-13-
Model W1835 (For Machines Mfg. Since 12/12)
ELECTRICAL
Polarized Plug
5-15 Receptacle
1-15 Plug
Neutral
Hot
Figure 3. NEMA 1-15 plug & receptacle.
For 120V Connection
Extension Cords
This tool is double-insulated and therefore does not have
a grounding wire or plug. The two-pronged, NEMA 1-15
plug has a polarized end; this means that one prong
(the neutral connector) is wider than the other (the
hot connector). Polarized plugs must be used only with
polarized receptacles. Do not attempt to plug this tool
into a non-polarized receptacle. If a polarized receptacle
is not available, a qualified electrical technician will have
to install one before the saw can be plugged in.
When using extension cords, make sure the cords are
rated for outdoor use. Outdoor use cords are marked with
a "W-A" or a "W" to signify their rating. Always check to
make sure that the extension cords are in good working
order and free of any type of damage, such as exposed
wires, cuts, creased bends, or missing prongs.
Extension cords cause voltage drop, which may damage
electrical components and shorten motor life. Voltage
drop increases as the extension cord size gets longer
and the gauge size gets smaller (higher gauge numbers
indicate smaller sizes. When using extension cords, always
choose the shortest cord possible, with the greatest-sized
gauge.
Below is a list of minimum gauge sizes needed for running
a 7-10 Amp tool at different lengths:
25 Feet .................................................. 16 AWG
50 Feet .................................................. 16 AWG
100 Feet ................................................ 14 AWG
This tool is equipped with a power cord that has an
equipment-grounding wire and NEMA 1-15 grounding plug.
The plug must only be inserted into a matching receptacle
(see Figure) that is properly installed and grounded in
accordance with local codes and ordinances.